In Calibration 83% 20 of 24 instruments Due in 30 Days 10 Calibrated, coming due Overdue 2 1 still marked in service Not Yet Calibrated 0 Do not use until calibrated On Hold or Away 2 Tagged out or at a provider OOT Reviews 4 3 waiting on a decision
9 of 18 items
Needs a Person Today Show All 18
Calibration · KZ-DIS-01 · Kalamazoo Pharma Dissolution 01 is overdue for calibration and still in service
Was due Oct 2. Calibrate it or tag it out today.
Out-of-tolerance review · OOT-016 · Wixom Precision Parts Thread Plug Gauge 11 failed its check Oct 3: 4 lots to assess, 8 lots possibly affected
Every use since Apr 6 is in question. Review each one and record the product decision.
Out-of-tolerance review · OOT-015 · Holland Food Distribution Trailer Recorder 207 failed its check Oct 6: 2 loads to assess, 1 load possibly affected
Every use since Sep 6 is in question. Review each one and record the product decision.
Out-of-tolerance review · OOT-014 · Kalamazoo Pharma Balance 02 failed its check Oct 8: 8 uses in 7 lots to assess, 6 lots possibly affected
Every use since Jul 9 is in question. Review each one and record the product decision.
Maintenance · PM-011 · Traverse Fresh Foods Belt tension and load cell inspection on Checkweigher 01 is overdue
10 days overdue. Do it and log it.
Calibration · GR-MIC-006 · Grand Rapids Devices Micrometer 006 calibration overdue since Oct 6
It is on hold, so it is not in use. Calibrate it in-house.
Reference standard · STD-BUF · Kalamazoo Pharma Certified pH buffers 4.01, 7.00, 10.01 certificate expired Oct 7
Do not calibrate against it until it is recertified.
Gauge R&R · MSA-002 · Wixom Precision Parts Gauge R&R on Height Gauge 01 waiting on a decision: may be acceptable, depending on use, 4 distinct categories
Accept the gauge, accept it with conditions or reject it.
Maintenance · PM-002 · Kalamazoo Pharma Lubricate the turret and check punch wear on Tablet Press 02 is overdue
1 day overdue. Do it and log it.
Calibrations done on time 98% ▼ -2 pts vs SepTarget at least 95%. Instruments in calibration 83% ▼ -13 pts vs SepTarget at least 95%. Found out of tolerance 9% ▲ +5 pts vs SepTarget at most 5%. Calibrations overdue 2 Target at most 0. Trend starts after 2 months of records. Receiving Inspection: 1 item Receiving Inspection 1 item Clean Room Assembly: 3 items Clean Room Assembly 3 items Metrology Lab: 2 items Metrology Lab 2 items Quarantine Cage Quarantine Cage Packaging & Labeling: 2 items Packaging & Labeling 2 items Finished Goods Finished Goods Caliper 014: Due this month Micrometer 006: On hold Torque Driver 03: In calibration CMM 01: In calibration Leak Tester 02: Due this month Pouch Sealer 04: In calibration Label Printer 01: No calibration needed Particle Counter 01: Due this month In calibration Due soon Overdue, held or not yet calibrated No calibration needed
Receiving Inspection Caliper 014: Due this monthMetrology Lab Micrometer 006: On hold CMM 01: In calibrationClean Room Assembly Torque Driver 03: In calibration Leak Tester 02: Due this month Particle Counter 01: Due this monthPackaging & Labeling Pouch Sealer 04: In calibration Label Printer 01: No calibration neededWall thickness and pin diameters in the metrology lab
Tolerance ±0.002 mm
Next due Oct 6 (6 days overdue)
Calibrated by In-house
Owner Owen Kowalski Open in the Register Record a Calibration
In calibration10 Due within 30 days10 Overdue2 Not yet calibrated0 On hold1 Out of service1 No calibration needed3 Retired2 Consensus standard: ISO 13485 7.6Regulation: 21 CFR 820.10(a)19 dated items
Coming Up, Next 30 Days Show All 19
Oct 12 today Take apart, wash and dry the dosing parts: Encapsulator 01 Maintenance · Kalamazoo Pharma · Ahmed Saleh Open Oct 13 tomorrow Full clean and line clearance at product changeover: Tablet Press 02 Maintenance · Kalamazoo Pharma · Tomás Herrera Open Oct 15 in 3 days Calibrate pH Meter 01 Calibration due · Kalamazoo Pharma · Keisha Monroe Open Oct 16 in 4 days Probe qualification on the reference sphere: CMM 01 Maintenance · Wixom Precision Parts · Pete Wojcik Open Oct 17 in 5 days Calibrate Probe Thermometer 07 Calibration due · Traverse Fresh Foods · Camila Reyes Open Oct 18 in 6 days Calibrate Dock Probe Thermometer 02 Calibration due · Holland Food Distribution · Omar Farouk Open Oct 24 in 12 days Calibrate Leak Tester 02 Calibration due · Grand Rapids Devices · Tyrone Jackson Open Oct 25 in 13 days Calibrate Particle Counter 01 Calibration due · Grand Rapids Devices · Tyrone Jackson Open Oct 25 in 13 days Recertify Flow reference for particle counters Standard recertification Open Oct 30 in 18 days Zero count check with the purge filter: Particle Counter 01 Maintenance · Grand Rapids Devices · Tyrone Jackson Open Nov 1 in 20 days Calibrate Reefer Unit 212 Calibration due · Holland Food Distribution · Victor Ramos Open Nov 1 in 20 days Reefer unit service: belts, refrigerant charge, defrost and controller check: Reefer Unit 212 Maintenance · Holland Food Distribution · Victor Ramos Open Where This Work Goes Next